Advantages:
 | Prevents moisture and vapor migration |
|
 | Penetrates concrete up to 7 inches |
|
 | Prevents alkali/efflorescence attack |
|
|
|
 | Prevents efflorescence |
|
 | Increases insulation R factor |
|
 | Improves weathering resistance |
|
 | Prevents chloride intrusion |
|
 | Prevents mildew and fungi |
|
 | Negative and positive side application |
|
 | Prevents flaking of paints |
|
 | Resists acid attack (see table below) * |
|
 | Adds density and bonding strength |
|
Acid
Type |
Concentration |
Exposure
1 |
Exposures
2-6 |
 | Resists freeze thaw (exceeds 360 cycles) to 2.8% loss by
weight |
|
Hydrochloric |
37% |
Surface
etched |
No
reaction |
 | Hydrostatic pressure to 100 psi (231 ft. below grade) |
|
Nitric |
70% |
Surface
etched |
No
reaction |
 | Preserves and prepares masonry for paints, coatings, and
adhesives |
|
Sulfuric |
98% |
Surface
etched |
No
reaction |
 | Cures concrete uniformly and increases surface hardness up
to 23 % |
|
Phosphoric |
85% |
No
reaction |
No
reaction |
Description:
MOXIE 1500 CONCRETE SEALER is water based, non-toxic, and
composed of in-organic, chemically reactive, complex compounds which allows full
penetration up to seven inches. MOXIE 1500 CONCRETE SEALER undergoes a chemical reaction
with the by products of the curing process to form the highest density of cementitious
materials, dramatically enhancing all of the natural characteristics of concrete and
reducing the capillary voids to practically zero.
Packaging:
MOXIE 1500 CONCRETE SEALER is available in the following
packages:
 | 55 gallon drum (US.) |
|
 | 5 gallon pails (US.) |
|
 | 1 gallon bottles (US.) |
|
Applicable Standards:
MOXIE 1500 CONCRETE SEALER meets or exceeds the following
performance specifications:
 | ASTM C 67, Sect. 25 and 29 |
|
 | ASTM C 156 |
|
 | USDA approved |
|
 | UDOT |
|
 | ASTM C-309 Performance Specifications * |
|
 | ASTM C 666 |
|
 | EPA approved |
|
 | VOC=0 |
|
Report of ASTM C-156 & C-309, Curing Properties, Loss
of Moisture Performance criteria:
Tests: Application rate 200 sq. ft. per gallon (two coats)
|
Loss of moisture: |
at 24 hr's. - 0.433k/m2 |
at 72 hr's. - 0.541k/m2 |
Preparatory Work:
Some steel troweled surfaces which have aged longer than 28
days may need to be shot blasted first, contact manufacturer. Any free or loose dirt,
grease, oil, efflorescence or foreign matter must be physically removed first.
Limitations:
MOXIE 1500 CONCRETE SEALER is formulated solely for
concrete and masonry products and should not be used on asphalt, metal, or wood products.
Will not penetrate acrylic or non-porous rubber base paint. Should not be applied below
40oF. MOXIE 1500 CONCRETE SEALER will seal against a hydrostatic pressure; however,
flowing water must be stopped before application. Very damp, cold days may extend drying
times. Higher temperature will shorten drying times.
Application:
Mist lightly with water prior to application. If acid
washing make sure acid is COMPLETELY REMOVED AND NEUTRALIZED prior to application.
Unless used as a curing agent it is recommended to wait no longer than 28 days before
application. Surface will still be porous enough to insure proper absorption. Earlier
application times are not deleterious and will result in higher compressive strengths. A
clean surface is required. Remove any wax, grease, rubber, acrylic based paint, or any
other type of surface sealer. Sand blasting, scarifying or bead/shotblasting may be
required to allow MOXIE 1500 CONCRETE SEALER to penetrate into the matrix of the concrete.
Two coats are required above grade; three coats below grade. Application method depends on
time and labor constraints, however, method "One" is preferred.
1) Application Method One: Apply two coats of
MOXIE 1500 CONCRETE SEALER 24 hours apart. Apply first coat by saturating the surface.
Broom out any puddling. On vertical surfaces allow approximately 12" rundown. When
this is nearly dry, MIST WITH WATER to promote deeper penetration. After 24 hours,
flood with water, allow to dry approx. 3 hours. REPEAT PROCESS FOR SECOND APPLICATION.
If efflorescence (white crystalline salts) appear continued flooding is necessary every 24
hours until efflorescence no longer appears. Typically two to seven days. .
2) Application Method Two: Apply first coat
by saturating the surface. Broom out any puddling. On vertical surfaces allow
approximately 12" rundown. When this is nearly dry, apply second coat. Allow
this to dry but not over 3 hours, then "mist" with water. After 24 hours, flood
surface as in APPLICATION METHOD ONE.
NOTE: High porosity, suspended lightweight structural, or
below-grade applications may require a third coat. Apply third coat 48 hours after the
second coat IN EITHER APPLICATION.
Curing:
The best concrete cure can be obtained with one heavy
application (approx. 250 to 300 sq. ft. per gallon) after initial set, prior to final
finish. To moisture/vapor or alkali/efflorescence-proof, proceed with APPLICATION
METHOD TWO.
Surface Coverage:
Two coat coverage will yield approximately 150 sq. ft. per
gallon, two coats. First coat will use about twice the amount of the second coat. A third
or fourth coat is usually required for stucco, gunite, shotcrete or mortar.
Precautions:
1. Due to pH level do not allow this
product to come in contact with plant life or leather. Do not allow product to come in
contact with glass, porcelain or ceramic tile, aluminum, zinc or galvanized steel.
Product
will permanently etch or erode the smooth surface. Must be rinsed with water or removed
with damp cloth immediately. DO NOT APPLY IN WINDY CONDITIONS.
2. Alkali salts (efflorescence) will
react with the carbon dioxide within 24 hrs. - 48 hrs. and become permanent calcium
carbonates unless flooding is performed every 24 hrs. until no more efflorescence is
present. If not, these salts will require physical removal such as wire brushing or
sandblasting.
Limited Warranty: 10 years
PROCEED TO TB
1501 TECHNICAL
CURING/MEMBRANE FORMING COMPOUNDS
PROCEED TO TB
1522 TECHNICAL BULLETIN
EFFLORESCENCE REMOVAL
PROCEED
TO TB
1536 TECHNICAL BULLETIN
VAPOR
BARRIERS, CORROSION INHIBITORS, CURING COMPOUNDS & BONDBREAKERS
PROCEED
TO TB
1587 TECHNICAL
SEALING OF POROUS CONCRETE MASONRY
UNITS (CMUS), CINDER, SPLIT FACE, ETC., BLOCK
PROCEED
TO MOXIE 1500 TEST PROCEDURES
DOWNLOAD
U.S. GOVERNMENT MATERIAL SAFETY DATA SHEET (MSDS) FOR MOXIE 1500 AS AN
ADOBE ACROBAT PDF DOCUMENT
DOWNLOAD
THIS PAGE AS AN ADOBE ACROBAT PDF DOCUMENT IN IT'S ORIGINAL FORMAT

|